Short answer: clean when normalised permeate flow falls, or differential pressure rises, by about 10–15% from your baseline — or when normalised salt passage rises noticeably. Use normalised data, not raw readings, because temperature and feed salinity change raw flow and pressure from day to day.
Why Raw Readings Mislead
RO output changes with temperature: colder seawater gives less permeate at the same pressure. Feed salinity, recovery and pressure also move. If you watch only raw permeate flow, you will either clean too often in winter or miss real fouling in summer. Normalisation corrects the readings back to standard conditions, so what is left is the change caused by fouling or scaling.
The Three Numbers to Track
| Indicator | What a change means | Typical cause |
|---|---|---|
| Normalised permeate flow falls | Membrane surface is being covered | Fouling or scaling |
| Differential pressure rises | Feed channels are being blocked | Biofouling, silt (first stage) or scale (last stage) |
| Normalised salt passage rises | More salt reaching the permeate | Scaling, membrane damage or O-ring leaks |
Setting Your Baseline
Take the baseline after the first days of stable operation following start-up or the last clean. Record it with temperature, feed conductivity, recovery and pressures. Every later reading is compared with that baseline.
The 10–15% Rule
Most plants clean when normalised permeate flow drops, or differential pressure rises, by about 10–15% from baseline. Cleaning at this point usually restores performance fully. Waiting until the drop is 25% or more often leaves deposits that a CIP cannot remove, and membrane life shortens.
Which Stage Tells You What
- First stage ΔP rising: usually biofouling or silt — check SDI, pretreatment and SBS dosing.
- Last stage ΔP and salt passage rising: usually scaling — check antiscalant dosing and recovery.
Acid or Alkaline First?
Acid cleaners remove carbonate scale and metal oxides such as iron. Alkaline and organic cleaners remove biofilm, organics and silt. Many plants need both in sequence. Where biofouling or organics are the main problem, an alkaline clean usually comes first so the acid can reach the scale underneath; where scale or iron dominate, acid may come first. Follow your membrane supplier's pH and temperature limits.
Keep a Cleaning Log
Record each clean: date, trigger, chemicals, pH, temperature, soak time and the normalised data before and after. Over a year this shows whether intervals are getting shorter — an early warning that pretreatment or antiscalant needs attention.
Related
Kranti Water supplies acid, alkaline and organic CIP cleaners and membrane biocide — see our desalination plant chemicals page. Our free RO recovery and salt rejection calculator gives a quick health check.
Questions
When should SWRO membranes be cleaned?
Typically when normalised permeate flow falls or differential pressure rises by about 10–15% from the baseline taken after start-up or the last clean.
Should RO membranes be cleaned with acid or alkaline first?
Alkaline first where biofouling or organics dominate, acid first where carbonate scale or iron dominate. Many plants use both in sequence within the membrane supplier’s limits.
Running an SWRO or BWRO plant?
Send us your feed-water analysis, recovery and membrane type. We'll recommend antiscalant, cleaning and pretreatment chemicals with dosages within 48 hours.
See Desalination Chemicals